Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Research Note
  • Published:

The effect of light level, CO2 flow rate, and anesthesia on the stress response of mice during CO2 euthanasia

Abstract

Euthanasia protocols are designed to mitigate the stress experienced by animals, and an environment that induces minimal stress helps achieve that goal. A protocol that is efficient and practical in a typical animal research facility is also important. Light intensity, isoflurane, and CO2 flow rate were studied for their impact on the stress response of mice during CO2 euthanasia. Behavior was observed and scored during euthanasia and serum corticosterone was measured immediately after death. Unsurprisingly, animals euthanized with a high-flow rate of CO2 became unconscious in the least amount of time, while animals euthanized with a low-flow rate required the most time to reach unconsciousness. There was a significant increase in anxious behaviors in animals in the isoflurane group (F1,12 = 6.67, P = 0.024), the high-flow rate CO2 group (F1,12 = 10.24, P = 0.007), and bright chamber group (F1,12 = 7.27, P = 0.019). Serum corticosterone was highest in the isoflurane group (124.72 ± 83.98 ng/ml), however there was no significant difference in corticosterone levels observed for the other study variables of light and flow-rate. A darkened chamber and low CO2 flow rates help to decrease stress experienced during CO2 euthanasia, while the use of isoflurane was observed to increase the stress response during euthanasia.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Figure 1: Average behavior scores recorded while observing animals during euthanasia.
Figure 2: All behaviors combined into one “anxiety behavior” value.
Figure 3: Average agitation scores recorded during euthanasia behavior observations.
Figure 4: The average time to unconsciousness for animals euthanized using high flow-rate CO2, low flow-rate CO2, and with isoflurane pre-anesthesia.

Similar content being viewed by others

References

  1. Leach, M.C. et al. Aversion to gaseous euthanasia agents in rats and mice. Comp. Med. 52, 249–257 (2002).

    CAS  PubMed  Google Scholar 

  2. McIntyre, A.R. et al. Automated mouse euthanasia in an individually ventilated caging system: system development and assessment. J. Am. Assoc. Lab. Anim. Sci. 46, 65–73 (2007).

    CAS  PubMed  Google Scholar 

  3. Taylor, D.K. & Mook, D.M. Isoflurane waste anesthetic gas concentrations associated with the open-drop method. J. Am. Assoc. Lab. Anim. Sci. 48, 61–64 (2009).

    CAS  PubMed  PubMed Central  Google Scholar 

  4. Burkholder, T.H. et al. Comparison of carbon dioxide and argon euthanasia: effects on behavior, heart rate, and respiratory lesions in rats. J. Am. Assoc. Lab. Anim. Sci. 49, 448–453 (2010).

    CAS  PubMed  PubMed Central  Google Scholar 

  5. Pritchett, K. et al. Euthanasia of neonatal mice with carbon dioxide. Comp. Med. 55, 275–281 (2005).

    CAS  PubMed  Google Scholar 

  6. Hazzard, K.C., Watkins-Chow, D.E. & Garrett, L.J. Method of euthanasia influences the oocyte fertilization rate with fresh mouse sperm. J. Am. Assoc. Lab. Anim. Sci. 53, 641–646 (2014).

    PubMed  PubMed Central  Google Scholar 

  7. Raj, A.B., Leach, M.C. & Morton, D.B. Carbon dioxide for euthanasia of laboratory animals. Comp. Med. 54, 470–471 (2004).

    CAS  PubMed  Google Scholar 

  8. National Research Council Committee on Recognition and Alleviation of Distress in Laboratory Animals. Recognition and alleviation of distress in laboratory animals (National Academies Press, Washington, D.C., 2008).

  9. Smith, W. & Harrap, S.B. Behavioural and cardiovascular responses of rats to euthanasia using carbon dioxide gas. Lab. Anim. 31, 337–346 (1997).

    CAS  PubMed  Google Scholar 

  10. Thomas, A.A., Flecknell, P.A. & Golledge, H.D. Combining nitrous oxide with carbon dioxide decreases the time to loss of consciousness during euthanasia in mice–refinement of animal welfare? PLoS ONE 7, e32290 (2012).

    CAS  PubMed  PubMed Central  Google Scholar 

  11. Pecaut, M.J. et al. Modification of immunologic and hematologic variables by method of CO2 euthanasia. Comp. Med. 50, 595–602 (2000).

    CAS  PubMed  Google Scholar 

  12. Dunn, J.D., Cometto-Muniz, J.E. & Cain, W.S. Nasal reflexes: reduced sensitivity to CO2 irritation in cigarette smokers. J. Appl. Toxicol. 2, 176–178 (1982).

    CAS  Google Scholar 

  13. Anton, F., Euchner, I. & Handwerker, H.O. Psychophysical examination of pain induced by defined CO2 pulses applied to the nasal mucosa. Pain 49, 53–60 (1992).

    CAS  PubMed  Google Scholar 

  14. Danneman, P.J., Stein, S. & Walshaw, S.O. Humane and practical implications of using carbon dioxide mixed with oxygen for anesthesia or euthanasia of rats. Lab. Anim. Sci. 47, 376–385 (1997).

    CAS  PubMed  Google Scholar 

  15. Wise, P.M., Wysocki, C.J. & Radil, T. Time–intensity ratings of nasal irritation from carbon dioxide. 28, 751–760 2003.

  16. Cooper, J., Mason, G. & Raj, M. Determination of the aversion of farmed mink (Mustela vison) to carbon dioxide. Vet. Rec. 143, 359–361 (1998).

    CAS  PubMed  Google Scholar 

  17. Raj, A.B. Aversive reactions of turkeys to argon, carbon dioxide and a mixture of carbon dioxide and argon. Vet. Rec. 138, 592–593 (1996).

    CAS  PubMed  Google Scholar 

  18. Llonch, P. et al. Stunning pigs with nitrogen and carbon dioxide mixtures: effects on animal welfare and meat quality. Animal 6, 668–675 (2012).

    CAS  PubMed  Google Scholar 

  19. Shusterman, D. & Avila, P.C. Real-time monitoring of nasal mucosal pH during carbon dioxide stimulation: implications for stimulus dynamics. Chem. Senses 28, 595–601 (2003).

    CAS  PubMed  Google Scholar 

  20. Hu, J. et al. Detection of near-atmospheric concentrations of CO2 by an olfactory subsystem in the mouse. Science 317, 953–957 (2007).

    CAS  PubMed  Google Scholar 

  21. Coates, E.L. Olfactory CO(2) chemoreceptors. Respir. Physiol. 129, 219–229 (2001).

    CAS  PubMed  Google Scholar 

  22. Dangers, L., Laviolette, L., Similowski, T. & Morélot-Panzini, C. Interactions between dyspnea and the brain processing of nociceptive stimuli: experimental air hunger attenuates laser-evoked brain potentials in humans. Front. Physiol. 6, 358 (2015).

    PubMed  PubMed Central  Google Scholar 

  23. Liotti, M. et al. Brain responses associated with consciousness of breathlessness (air hunger). Proc. Natl. Acad. Sci. 98, 2035–2040 (2001).

    CAS  PubMed  Google Scholar 

  24. Artwohl, J. et al. Report of the ACLAM Task Force on Rodent Euthanasia. J. Am. Assoc. Lab. Anim. Sci. 45, 98–105 (2006).

    CAS  PubMed  Google Scholar 

  25. American Veterinary Medical Association. AVMA Guidelines for the Euthanasia of Animals: 2013 Edition, 2013 (https://www.avma.org/KB/Policies/Documents/euthanasia.pdf).

  26. Moody, C.M., Chua, B. & Weary, D.M. The effect of carbon dioxide flow rate on the euthanasia of laboratory mice. Lab. Anim. 48, 298–304 (2014).

    CAS  PubMed  Google Scholar 

  27. Sadler, L.J. et al. Effects of flow rate and gas mixture on the welfare of weaned and neonate pigs during gas euthanasia. J. Anim. Sci. 92, 793–805 (2014).

    CAS  PubMed  Google Scholar 

  28. Sharp, J., Azar, T. & Lawson, D. Comparison of carbon dioxide, argon, and nitrogen for inducing unconsciousness or euthanasia of rats. J. Am. Assoc. Lab. Anim. Sci. 45, 21–25 (2006).

    CAS  PubMed  Google Scholar 

  29. Wong, D., Makowska, I.J. & Weary, D.M. Rat aversion to isoflurane versus carbon dioxide. Biol. Lett. 9, 20121000 (2012).

    PubMed  Google Scholar 

  30. Leach, M.C. et al. Degrees of aversion shown by rats and mice to different concentrations of inhalational anaesthetics. Vet. Rec. 150, 808–815 (2002).

    CAS  PubMed  Google Scholar 

  31. Valentine, H., Williams, W.O. & Maurer, K.J. Sedation or inhalant anesthesia before euthanasia with CO2 does not reduce behavioral or physiologic signs of pain and stress in mice. J. Am. Assoc. Lab. Anim. Sci. 51, 50–57 (2012).

    CAS  PubMed  PubMed Central  Google Scholar 

  32. Becker, K. et al. Low dose isoflurane exerts opposing effects on neuronal network excitability in neocortex and hippocampus. PLoS ONE 7, e39346 (2012).

    CAS  PubMed  PubMed Central  Google Scholar 

  33. Komatsu, H. & Ogli, K. Opisthotonus during exposure to isoflurane, enflurane, and halothane in mice. Anesthesiology 67, 771–774 (1987).

    CAS  PubMed  Google Scholar 

  34. Bowen, M.T. et al. Aggregation in quads but not pairs of rats exposed to cat odor or bright light. Behav. Processes 90, 331–336 (2012).

    PubMed  Google Scholar 

  35. Huang, Y., Zhou, W. & Zhang, Y. Bright lighting conditions during testing increase thigmotaxis and impair water maze performance in BALB/c mice. Behav. Brain Res. 226, 26–31 (2012).

    PubMed  Google Scholar 

  36. Krysiak, M.E. et al. The effect of ecologically relevant variations in light level on the performance of Mongolian gerbils on two visual tasks. Behav. Processes 88, 135–141 (2011).

    PubMed  Google Scholar 

  37. Takao, K. & Miyakawa, T. Light/dark transition test for mice. J. Vis. Exp. 13, 104 (2006).

    Google Scholar 

  38. Miller, S.M., Piasecki, C.C. & Lonstein, J.S. Use of the light-dark box to compare the anxiety-related behavior of virgin and postpartum female rats. Pharmacol. Biochem. Behav. 100, 130–137 (2011).

    CAS  PubMed  PubMed Central  Google Scholar 

  39. Institute for Laboratory Animal Research. Guide for the Care and Use of Laboratory Animals 8th edn. (National Academies Press, Washington, DC, 2011).

  40. Semple-Rowland, S.L. & Dawson, W.W. Retinal cyclic light damage threshold for albino rats. Lab. Anim. Sci. 37, 289–298 (1987).

    CAS  PubMed  Google Scholar 

  41. Chakravarti, S. & Basu, S. Modern anaesthesia vapourisers. Indian J. Anaesth. 57, 464–471 (2013).

    PubMed  PubMed Central  Google Scholar 

  42. Bowers, S.L. et al. Stressor-specific alterations in corticosterone and immune responses in mice. Brain Behav. Immun. 22, 105–113 (2008).

    CAS  PubMed  Google Scholar 

  43. De Boer, S.F. et al. Plasma catecholamine, corticosterone and glucose responses to repeated stress in rats: effect of interstressor interval length. Physiol. Behav. 47, 1117–1124 (1990).

    CAS  PubMed  Google Scholar 

  44. Girard-Joyal, O. et al. Age and sex differences in c-Fos expression and serum corticosterone concentration following LPS treatment. Neuroscience 305, 293–301 (2015).

    CAS  PubMed  Google Scholar 

  45. Gong, S. et al. Dynamics and correlation of serum cortisol and corticosterone under different physiological or stressful conditions in mice. PLoS ONE 10, e0117503 (2015).

    PubMed  PubMed Central  Google Scholar 

  46. Vahl, T.P. et al. Comparative analysis of ACTH and corticosterone sampling methods in rats. Am. J. Physiol. Endocrinol. Metab. 289, E823–E828 (2005).

    CAS  PubMed  Google Scholar 

  47. Nyuyki, K.D. et al. Comparison of corticosterone responses to acute stressors: chronic jugular vein versus trunk blood samples in mice. Stress 15, 618–626 (2012).

    PubMed  Google Scholar 

  48. Zamora-Gonzalez, E.O. et al. A chronic combinatory stress model that activates the HPA axis and avoids habituation in BALB/C mice. J. Neurosci. Methods 213, 70–75 (2013).

    CAS  PubMed  Google Scholar 

  49. Tuli, J.S., Smith, J.A. & Morton, D.B. Corticosterone, adrenal and spleen weight in mice after tail bleeding, and its effect on nearby animals. Lab. Anim. 29, 90–95 (1995).

    CAS  PubMed  Google Scholar 

  50. Denmark, A. et al. The effects of chronic social defeat stress on mouse self-grooming behavior and its patterning. Behav. Brain Res. 208, 553–559 (2010).

    PubMed  Google Scholar 

  51. Hyde, J.F. & Jerussi, T.P. Sexual dimorphism in rats with respect to locomotor activity and circling behavior. Pharmacol. Biochem. Behav. 18, 725–729 (1983).

    CAS  PubMed  Google Scholar 

  52. Deacon, R.M. Digging and marble burying in mice: simple methods for in vivo identification of biological impacts. Nat. Protoc. 1, 122–124 (2006).

    CAS  PubMed  Google Scholar 

  53. Conlee, K.M. et al. Carbon dioxide for euthanasia: concerns regarding pain and distress, with special reference to mice and rats. Lab. Anim. 39, 137–161 (2005).

    CAS  PubMed  Google Scholar 

  54. Hewett, T.A. et al. A comparison of euthanasia methods in rats, using carbon dioxide in prefilled and fixed flow rate filled chambers. Lab. Anim. Sci. 43, 579–582 (1993).

    CAS  PubMed  Google Scholar 

  55. Rault, J.L. et al. Nitrous oxide as a humane method for piglet euthanasia: Behavior and electroencephalography (EEG). Physiol. Behav. 151, 29–37 (2015).

    CAS  PubMed  Google Scholar 

  56. Al-Mousawi, A.M. et al. Impact of anesthesia, analgesia, and euthanasia technique on the inflammatory cytokine profile in a rodent model of severe burn injury. Shock 34, 261–268 (2010).

    CAS  PubMed  PubMed Central  Google Scholar 

  57. Johnson, R.A. et al. Comparison of isoflurane with sevoflurane for anesthesia induction and recovery in adult dogs. Am. J. Vet. Res. 59, 478–481 (1998).

    CAS  PubMed  Google Scholar 

  58. Altholtz, L.Y. et al. Comparison of the stress response in rats to repeated isoflurane or CO2:O2 anesthesia used for restraint during serial blood collection via the jugular vein. J. Am. Assoc. Lab. Anim. Sci. 45, 17–22 (2006).

    CAS  PubMed  Google Scholar 

  59. Blom, H.J. et al. Preferences of mice and rats for types of bedding material. Lab. Anim. 30, 234–244 (1996).

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to acknowledge the contributions of Kristy Weed and Maya Meeks who assisted with blood collection and behavioral observations. Also Geary Smith who assisted with sample submission and behavioral observations.

Author information

Authors and Affiliations

Authors

Contributions

K.P. conceived the idea for the project. K.P. and D.T. designed the experiments. K.P. carried out the experiments. K.E., K.P., and D.K.T. analyzed the data. K.P. wrote the manuscript. D.K.T. supervised the project.

Corresponding author

Correspondence to Karin Powell.

Ethics declarations

Competing interests

The authors declare no competing financial interests.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Powell, K., Ethun, K. & Taylor, D. The effect of light level, CO2 flow rate, and anesthesia on the stress response of mice during CO2 euthanasia. Lab Anim 45, 386–395 (2016). https://doi.org/10.1038/laban.1117

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/laban.1117

This article is cited by

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing